EnGenius EGS7228P User Manual Page 36

  • Download
  • Add to my manuals
  • Print
  • Page
    / 151
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 35
36
LACP Timeout
Link Aggregation Control Protocol (LACP) allows
the exchange of information with regard to the link
aggregation between two members of aggregation. The
LACP Time Out value is measured in a periodic interval.
Checkrstwhethertheportinthetrunkgroupisup.
When the interval expires, it will be removed from the
trunk. Set a Short Timeout (one second) for busy trunked
links to ensure that disabled ports are removed from the
trunk group as soon as possible. The default value for
LACP time out is: Long Timeout.
Timeout: Select the administrative LACP timeout.
Long – Long timeout value.
Short – Short timeout value.
Long:
The LACP PDU will be sent for every 30 seconds, and
the LACP timeout value is 90 seconds.
Short:
The LACP PDU will be sent every second. The
timeout value is 3 seconds.
Apply: Click APPLY to update the the system settings.